User’s Manual - mediaMAX MINI HD
ENGLISH
Reserved of technical modifi cations and/or errors
rev 1.2
To identify a signal, to do it with a span of 50 MHz is advised (default value in cable). For select it, use
left and right arrows keys. The span current value is shown at the left bottom part of the monitor.
With the spectrum on screen, move the rotary wheel to sweep the frequency band to spot the target
signal. If only spectrum is needed on the monitor, press the buttom
“spectrum” to active it.
In cable band,
“nav” key selects only frequency mode to sweep the band normally by frequency with
100 KHz steps.
10.3.3 Measurement selection
With the target signal identifi ed, it’s necessary to select the signal type (analog or digital). Press
“op-
tions”
key, select “Carrier mode” and there will be two differents options:
Analog: if analog signal
Digital: if digital signal
Select one of them and confi rm clicking the wheel.
For digital cable signal, it is necessary setup signal parameters. Select “Digital modulation”. It is
necessary to setup the following parameters:
1. Symbol rate: This parameter should be fi xed according to the Bit Rate (symbol rate) of
the channel, data which is supplied by the operador.
2. Spectrum inversion: Pushing on this fi eld, you can see the following options:
- Auto: Enables the automatic way of spectrum inversion.
- On: Enables the manual way of spectrum inversion.
- Off: Disables the manual spectrum inversion.
You should enabled in case it is necessary to invert the spectrum. If you select inco-
rrectly the inversion of the spectrum, the reception will be not correct.